As the complexity and criticality of electric vehicle (EV) charging infrastructure increases, the need for robust and transparent diagnostic capabilities in charging stations and other OCPP enabled devices becomes paramount. Currently, the Open Charge Point Protocol (OCPP) lacks a standardized mechanism to explicitly define, trigger, and monitor e.g. self and integration tests within its device model and message set. This gap leads to proprietary extensions, inconsistent implementations, and reduced interoperability across manufacturers and management systems on top of the specified generic device model reporting, diagnostic and logging mechanisms.

An explicit diagnostics model, tightly integrated into the OCPP device model and messsage framework, would enable charging station operators to reliably enumerate, parameterize, and execute a wide range of diagnostics — ranging from simple software integrity self checks, over complex hardware validation routines to integration tests within the charging station operator network. By describing available tests, their required parameters, operational constraints, intermediate reports, and expected outcomes in a machine-readable and discoverable manner, operators gain better tools for remote maintenance, troubleshooting, and regulatory compliance.

Importantly, self tests should not only be accessible for manual execution by human operators or for periodic automated routines, but also be available to intelligent software agents and AI-based diagnostic systems. Such agents can proactively trigger or sequence self tests in response to anomalies, performance degradation, or security incidents, enabling more effective root cause analysis and faster problem resolution within the charging infrastructure.

Moreover, standardized test models support automation of periodic health checks, real-time fault isolation, and evidence-based reporting for quality assurance and cybersecurity audits. It also facilitates seamless backend integration, future-proofing OCPP deployments against evolving reliability and safety requirements in critical infrastructure like the upcoming European Network and Information Systems 2 (NIS2) Directive. Therefore, the introduction of a formal self test model in OCPP and related protocols is essential for improving the transparency, resilience, and maintainability of EV charging networks.

Scope

This subchapter provides a differentiation between various diagnostic test types that can be performed by charging stations and other OCPP devices. By clearly outlining the purpose and scope of each test type, this section ensures consistent terminology and lays the foundation for advanced diagnostics and automated monitoring of the entire charging infrastructure.

Test Type Support Role and Description Example
Diagnostic Control yes A normal OCPP request sent to read or set internal state or simulate interactions that are out-of-scope of the normal OCPP communication. Simulate the swiping of a RFID card for starting an authorization and charging process.
Self Test yes A test executed locally and autonomously by the charging station to verify the integrity and correct functioning of its internal hardware and software components, independent of external systems. Self-tests can be triggered on demand, scheduled, or during startup, and provide detailed diagnostic results on the internal health status of the device. Testing the reachability of the internal energy meter connected via RS485 and Modbus/RTU.
Integration Test yes A test performed by the charging station to verify the correct operation and connectivity of external interfaces, dependencies, and services such as backends, network infrastructure, or peripheral devices. Integration tests ensure the station is correctly embedded in its operational environment and can communicate as expected. Testing the reachability and rootCAs of Network Time Secure legal servers.
Health Check yes A lightweight, often automated status assessment that provides a quick, aggregated indicator of the station’s general operational state. Health checks may combine results from self-tests and integration tests but are not intended to replace detailed diagnostics. Typically used for monitoring or liveness endpoints. Enough RAM, flash storage and free CPU cycles to start new charging sessions.
Security Test maybe later A test aimed at verifying the robustness of the station’s cybersecurity measures, including authentication, authorization, data integrity, and secure communication. Security tests may simulate attack vectors or check the validity and expiration of cryptographic credentials. No well-known unsecure configuration settings had been detected.
Compliance Test maybe later A test that verifies whether the charging station adheres to relevant regulatory, safety, or protocol standards. Compliance tests may include both self-test and integration-test elements and are essential for audits, certifications, or market access. No well-known unsafe grid code configuration settings had been detected.
Performance Test maybe later A test that measures the station’s behavior under defined workloads or stress scenarios, focusing on timing, throughput, and resource consumption. Performance tests help identify bottlenecks and ensure the device meets operational requirements under load. Response time and total time until the entire device model was reported. Number of concurrent monitoring data streams supported. Time to process complex charging profiles.

Current State of the Art

This chapter gives a short overview which kind of diagnostic functions are already available within the current OCPP v2.1 version.

GetBaseReport

Function Query full or partial device/component inventory, including firmware/software versions (for diagnostic/audit purposes).
Usage CSMS requests; Charge point responds with inventory tree.

GetReport

Function Request specific diagnostic data or variables from components (e.g., power electronics health, communication state).
Schema Filtered by component or variable name.
References OCPP 2.0.1, section 4.5.2

GetLog

Function Remote download of log files (e.g., error logs, operational logs).
Usage CSMS (central system) requests specific logs from EVSE.
Schema GetLogRequest fields: logType, requestId, retries, retryInterval, log, logParameters (start/end time, remote location, etc.)
Response fields status, filename/location
References OCPP 2.0.1, section 14.5

LogStatusNotification

Function Notify CSMS about the status of log upload (Started, Success, Failed, etc.)
Usage EVSE reports back upload status after GetLog.
Schema requestId, status (enum)

TriggerMessage

Function Central system can instruct EVSE to trigger specific events, e.g., send a StatusNotification, or in future, initiate self-test (where supported).
Schema requestedMessage (e.g., StatusNotification, BootNotification), optional evseId, connectorId

Note: OCPP 2.1 introduces extendable types to include e.g. "SelfTest" or "HealthCheck" as triggerable messages, but (optional) parameters on triggers are missing.

EventNotification

Function Report real-time component-level events, errors, warnings (component name, event type, severity, timestamp, technical details).
Schema Extensive; supports component, eventType, eventId, severity, etc.
References OCPP 2.0.1, section 2.3.2

Diagnostic Control

New Diagnostic Control requests provide a standardized mechanism to remotely read and manipulate the internal state of components such as charging stations. This extension is designed specifically to support advanced testing, simulation, and validation workflows during development, deployment, or maintenance.

It enables simulation of physical interactions, like the swiping of an RFID card, entirely through software. This allows triggering of typical sequences like RFID UID detection, authorization, and initiation of a charging session without requiring physical presence or hardware interaction.

Beyond behavioral simulation, Diagnostic Control may also permit direct manipulation of internal system state, including the setting of Device Model Variables that are normally read-only under standard OCPP access control policies. This allows validation of edge cases, failure modes, or system behavior under specific manipulated conditions that would otherwise be difficult or impossible to reproduce.

Unlike traditional OCPP requests, Diagnostic Control requests are not part of the normal operational interface, but instead serve as diagnostic and testing tools. These requests and their corresponding responses follow the same message structure as regular OCPP operations. However, they are distinguished by the strong requirement for digital signatures, verifiably issued by an entity that holds explicit Diagnostic Control access rights.

This cryptographic enforcement ensures that only authorized diagnostic tools or operators can issue such requests. As a result, it is considered safe and compliant to keep this interface active even in production environments, since misuse by unauthorized parties is effectively prevented through cryptographic validation.

GetExecutingEnvironment

This request returns information about the executing environment of the software under test. Especially when an embedded software is run within an emulator or a multi-user operating system and it hangs within an endless loop or crashed in unexpected ways, it is usefull to find out more details about its executing environment. By this for example the process identifiction might be retrieved to be able to kill -9 and to restart the process. Also alternative ways to initiate a hard restart or to download a memory image might be exposed.

OCPP v1.6

GetExecutingEnvironmentRequest:

Property M/O Type JSON Type Description
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

GetExecutingEnvironmentResponse:

The response can contain any data the executing environment wants to share with the user that optionally signed the request. This also means, that different users might see different information. It is good practise to describe the collection of data via a JSON-LinkedData (JSON-LD) @context property.

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
processId O ProcessId Number (Integer > 0) The process identification of the main application process.
restartURL O URL String An URL that can be called to kill and restart the entire process, e.g. tcp://192.168.178.23:8123 or *http://192.168.178.23:8123*.|
restartSecret O String String A long string acting as shared secret to kill and restart the entire process. The restartURL determines the actual usage, e.g. sending this string as TCP data or POSTing it to the given HTTP URL.
...any... O ... ... ...
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

GetExecutingEnvironmentRequest:

Property M/O Type JSON Type Description
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

GetExecutingEnvironmentResponse:

The response can contain any data the executing environment wants to share with the user that optionally signed the request. This also means, that different users might see different information. It is good practise to describe the collection of data via a JSON-LinkedData (JSON-LD) @context property.

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
processId O ProcessId Number (Integer > 0) The process identification of the main application process.
restartURL O URL String An URL that can be called to kill and restart the entire process, e.g. tcp://192.168.178.23:8123 or *http://192.168.178.23:8123*.|
restartSecret O String String A long string acting as shared secret to kill and restart the entire process. The restartURL determines the actual usage, e.g. sending this string as TCP data or POSTing it to the given HTTP URL.
...any... O ... ... ...
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

AdjustTimeScale

This request is a diagnostic extension to OCPP that enables external test tools or validation frameworks to temporarily alter the rate at which simulated time progresses within a charging station or associated components. This feature is particularly valuable in testing scenarios that depend on elapsed time, such as the automatic stop of a charging session after a specified duration, authorization timeouts, or inactivity handling. By accelerating or decelerating the passage of time for internal logic, long-running tests can be executed significantly faster, or timers can be frozen for controlled debugging.

The request specifies a timeScale value, which is a positive decimal number representing the multiplier applied to simulated time. A value of 1.0 indicates normal time progression, while a value of 2.0 causes internal time to progress twice as fast as real time. A value of 0.5 slows time down by half, and a value of 0.0 effectively pauses all time-based logic in the affected domain. To prevent unintended permanent changes, the request may optionally include a duration parameter (in seconds), after which the time scale automatically reverts to the normal value of 1.0.

This request is intended solely for testing and validation purposes in non-production environments. Charging stations operating in production mode may reject this request unless explicitly configured to permit it under controlled conditions. The response to such a request includes a status field indicating whether the operation was accepted, rejected, or not supported, and may optionally return the actually applied time scale, which might be capped or adjusted internally for implementation or safety reasons.

OCPP v1.6

AdjustTimeScaleRequest:

Property M/O Type JSON Type Description
scale M Double Number (Double) The time scale.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

AdjustTimeScaleResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

AdjustTimeScaleRequest:

Property M/O Type JSON Type Description
scale M Double Number (Double) The time scale.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

AdjustTimeScaleResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

TimeTravel

This request enables controlled manipulation of the system clock on a charging station or related component. Unlike the AdjustTimeScale request, which affects only the relative flow of internal time, TimeTravel allows the system to temporarily jump forward or backward in time, for example to simulate behavior under certificate expiration, daylight saving changes, authorization token expiry, dynamic tariff changes, or to validate metrological timestamp boundaries. Optionally, it may also define a duration, after which the system clock reverts to the original (real) time source. If no duration is specified, the simulated time remains active until explicitly reset or overridden by a subsequent request.

This request is intended solely for testing and validation purposes in non-production environments. Charging stations operating in production mode may reject this request unless explicitly configured to permit it under controlled conditions.

OCPP v1.6

TimeTravelRequest:

Property M/O Type JSON Type Description
timestamp M Timestamp String (ISO8601) The timestamp to travel to (UTC or with time zone offset).
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

TimeTravelResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

TimeTravelRequest:

Property M/O Type JSON Type Description
timestamp M Timestamp String (ISO8601) The timestamp to travel to (UTC or with time zone offset).
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

TimeTravelResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

Charging Station Diagnostics

SetErrorState

This request simulates an Error State within the entire charging station or within one of its EVSEs. When the charging station for example detects an upstream grid supply anomaly like undervoltage, overvoltage, or a phase failure, is must log, report and propagate this error state to one or more of its EVSEs. These EVSEs can then enter a PowerQualityError or GridFault state and signal the reduced-availability or fault indication via the Control Pilot (CP) to the EV. As a consequence, the charging process may be paused, limited, or aborted, depending on the error severity and the EV's response strategy.

OCPP v1.6

SetErrorStateRequest:

Property M/O Type JSON Type Description
faultType M FaultType String VoltageHigh | VoltageLow | PhaseLoss | ResidualCurrent | ...
connectorId O ConnectorId Number (Integer) The optional connector identification, when the charging station has more than one connector (0 > ConnectorId ≤ MaxConnectorId).
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
duration O TimeSpan Number (ms) An optional duration of the error state for short transient errors.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetErrorStateResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

SetErrorStateRequest:

Property M/O Type JSON Type Description
faultType M FaultType String VoltageHigh | VoltageLow | PhaseLoss | ResidualCurrent | ...
evse O EVSE Object The optional EVSE and connector identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId) and (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
duration O TimeSpan Number (ms) An optional duration of the error state for short transient errors.
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

SetErrorStateResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SwipeRFIDCard

This request simulates the swiping of an RFID card triggering RFID UID detection, authorization, and maybe the start of a charging session without requiring physical presence or hardware interaction. The same mechanism can also be used to terminate an active charging session, either by simulating the swipe of the same RFID card used to initiate the session, or by simulating a swipe of another card that belongs to the same authorization group.

OCPP v1.6

SwipeRFIDCardRequest:

Property M/O Type JSON Type Description
idTag M IdTag String The identification tag, e.g. of the RFID card to be swiped.
readerId O ConnectorId Number (Integer) The optional RFID reader identification, when the charging station has more than one connector and therefore more than one RFID reader or an additional user interface process to select a specific connector before or after swiping the RFID card (0 > ReaderId ≤ MaxConnectorId).
simulationMode O IdTagSimulationMode String An optional simulation mode: Software\|Hardware\|...
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SwipeRFIDCardResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

SwipeRFIDCardRequest:

Property M/O Type JSON Type Description
idToken M IdToken Object The identification token, e.g. of the RFID card to be swiped.
readerId O EVSEId Number (Integer) The optional RFID reader identification, when the charging station has more than one EVSE and therefore more than one RFID reader or an additional user interface process to select a specific EVSE/connector before or after swiping the RFID card (0 > ReaderId ≤ MaxEVSEId).
simulationMode O IdTokenSimulationMode String An optional simulation mode: Software\|Hardware\|...
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SwipeRFIDCardResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetResidualCurrent (ToDo)

Detects AC/DC leakage currents (e.g., ground faults) by comparing incoming/outgoing current; trips power if imbalance exceeds thresholds (e.g., 6mA DC or 30mA AC). Types: A (AC + pulsating DC), B (full AC/DC including smooth DC). Often paired with RDC-DD for DC monitoring.

(see also: IEC 62955)

SetInsulationResistor (ToDo)

An Insulation Monitoring Device (IMD) monitors the insulation resistance between the electrical system (e.g., DC lines) and ground to detect faults like short circuits or degradation that could lead to electric shocks or fires.

(see also: IEC 62955)

SetTemperature (ToDo)

Monitors charging station and/or ambient temperatures to prevent overheating.

SetDoorOpen (ToDo)

Some charging station manufacturers have a simple "door open" sensor.

SetIntrusionDetection (ToDo)

Some charging station manufacturers have some sort of "Intrusion Detection", that disables the charging station until explicitly "unlocked" by service personal.

CCS Diagnostics

The following messages define diagnostics for the Combined Charging System (CCS).

AttachCable

This request simulates the connection of a detached charging cable to the EVSE socket of an AC charging station.

The request includes a Proximity Pilot (PP) resistor value, which represents the EV driver's AC charging cable maximum permissible current according to IEC 61851-1 and IEC 62196-2. This resistor is physically located within the plug between PP and PE. The EVSE uses a voltage divider to detect the maximum allowed current of the cable by placing a voltage (typically +5 V) on the PP line via a pull-up resistor. The EVSE then reads the resulting voltage and infers the PP resistor value. The following lookup table translates the resistor value to the maximum allowed current.

PP Resistor Max Current Voltage at PP Tolerance
∞ Ω Cable not connected
EV unplugged
+5.0 V —
1500 Ω 13 A +2.0 V ±5%
680 Ω 20 A +1.8 V ±5%
220 Ω 32 A +0.9 V ±5%
100 Ω 63 A +0.45 V ±5%
Other / Out-of-spec Invalid / undefined < 0.25 V or unrecognized value —

Even when to charging cable is first connected to the EV and afterwards to an EVSE socket of a charging station, the attachment of this cable does not imply that an EV will be detected.

OCPP v1.6

AttachCableRequest:

Property M/O Type JSON Type Description
connectorId M ConnectorId Number (Integer) The connector identification, when the charging station has more than one connector (0 > ConnectorId ≤ MaxConnectorId).
resistorValue M Ohm Number (Double) The resistor value >0 to indicate the cable's maximum permissible current.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

AttachCableResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

AttachCableRequest:

Property M/O Type JSON Type Default Description
evseId M EVSEId Number (Integer) - The EVSE identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId).
connectorId O ConnectorId Number (Integer) 1 The optional connector identification, when the charging station has more than one connector on the given EVSE (0 > ConnectorId ≤ MaxConnectorId(EVSEId)). Default: 1
resistorValue M Ohm Number (Double) - A resistor value >0 to indicate the cable's maximum permissible current.
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

AttachCableResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

GetPWMValue

This request retrieves the current value of the Pulse Width Modulation (PWM) signal generated by the EVSE's Control Pilot. The PWM duty cycle represents the maximum allowable charging current as defined by IEC 61851-1 and is used by the EV to determine the upper limit of the energy it may draw from the EVSE. Reading this value allows diagnostic systems to verify the dynamic current limits being communicated by the charging station to the vehicle in real-time, which is essential for safe and standards-compliant operation.

OCPP v1.6

GetPWMValueRequest:

Property M/O Type JSON Type Description
connectorId M ConnectorId Number (Integer) The connector identification, when the charging station has more than one connector (0 > ConnectorId ≤ MaxConnectorId).
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

GetPWMValueResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

OCPP v2.x might prefer setting up a Device Model reporting.

GetPWMValueRequest:

Property M/O Type JSON Type Description
evseId M EVSEId Number (Integer) The EVSE identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId).
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

GetPWMValueResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetCPVoltage

IEC 61851-1 defines charging states called: A, B, C, D, E, F. They indicate whether the vehicle is connected, ready to charge, charging, or in a fault state.

The EV communicates its charging intend to the EVSE by modifying the voltage on the Control Pilot (CP) pin. Voltages are measured between the CP line and protective earth (PE) with a typical ±0.5 V tolerance.

For AC charging a Pulse Width Modulation (PWM) signal within the states B, C, and D indicates the maximum current the EVSE can supply. The duty cycle of the PWM correlates to the available current.

DC charging a high-level digital communication according to DIN 70121, ISO 15118-2 or ISO 15118-20 is used.

CP Voltage State PWM EV Condition Notes
+12 V A - Not connected No EV present
+9 V B PWM Connected, not requesting energy EV connected, ready for negotiation, not charging
+6 V C PWM Connected and ready to charge EV requests charging, internal contactor closed. Locked cable on EV side
+3 V D PWM Charging with ventilation required (rare) EV requests charging, requires external ventilation (e.g. battery gas exhaust)
0 V E - Error, CP short to PE or GND Fault or disconnected EVSE
< 0 V F - Error, reverse polarity or other fault Communication fault / Invalid voltage detected
>12 V - - Error, overvoltage fault Out-of-specification error / Invalid voltage detected

The following table shows all legal transitions between EV Charge Pilot states.

State Transition Allowed Description
A → B ✅ EV plugged in. EVSE detects vehicle, prepares for charging. No power is supplied yet.
A → C ❌ GoTo B first!
A → D ❌ GoTo B first!
A → E ⚠️ Implies hard fault (e.g., CP shorted to PE or GND), likely due to broken cable or EV.
A → F ⚠️ Illegal CP signaling (e.g., negative voltage); could indicate reverse wiring or short.
B → A ✅ EV unplugged.
B → C ✅ EV ready to charge, closes internal contactor. EVSE maybe locks detached charging cable, supplies power to the vehicle.
B → D ✅ Like state C, but EV requires ventilation (rare, obsolete in most modern EVs). EVSE activates ventilation.
B → E ⚠️ Possible fault if CP pulled to GND unexpectedly.
B → F ⚠️ Illegal CP voltage (e.g. < 0 V); wiring fault or hardware defect.
C → A ❌ Direct transitions from charging to disconnected are not possible without passing through B, as unplugging during charging is detected as a fault (→ E).
C → B ✅ EV pauses charging, e.g. due to State-of-Charge (SoC) or thermal reasons.
C → D ⚠️ Direct switching between ventilation and non-ventilation charging states is not standard; the EV typically returns to state B first!
C → E ⚠️ Implies unexpected CP fault during active charging – possibly unplugged during charge. EVSE stops power supply.
C → F ⚠️ Implies invalid signal level during charge – usually treated as fault. EVSE stops power supply or can no longer supply energy.
D → A ❌ Direct transitions from charging to disconnected are not possible without passing through B, as unplugging during charging is detected as a fault (→ E).
D → B ✅ Ventilation no longer required.
D → C ⚠️ Direct switching between ventilation and non-ventilation charging states is not standard; the EV typically returns to state B first!
D → E ⚠️ Implies CP pulled to GND during ventilation-required charging. Fault condition. EVSE stops power supply.
D → F ⚠️ Implies invalid signal level during charge – usually treated as fault. EVSE stops power supply or can no longer supply energy.
E → A ✅ Error resolved. EV unplugged.
E → B ✅ Error resolved. EV still connected.
E → C ⚠️ Error state requires resolution (often returning to A or B) before charging can resume.
E → D ⚠️ Error state requires resolution (often returning to A or B) before charging can resume.
E → F ⚠️ Usually irrelevant but can occur during unstable or cascading errors and faults.
F → A ✅ EVSE fault resolved. EV unplugged.
F → B ✅ EVSE fault resolved. EV still connected.
F → C ⚠️ Fault state requires resolution (often returning to A or B) before charging can resume.
F → D ⚠️ Fault state requires resolution (often returning to A or B) before charging can resume.
F → E ⚠️ Usually irrelevant but can occur during unstable or cascading errors and faults.
  +-----+     Plug-In      +-----+    Contactor Close    +-----+
  |  A  | ---------------> |  B  | --------------------> | C/D |
  +-----+                  +-----+     Supply Energy     +-----+
     ^                       | ^                            |
     |        Unplug         | |      Pause Charging        |
     +-----------------------+ +----------------------------+

OCPP v1.6

SetCPVoltageRequest:

Property M/O Type JSON Type Description
voltage M Volt Number (Double) The voltage on the Charge Pilot.
voltageError O Percent Number (Double) An optional random variation within ±n% to simulate real-world analog behavior.
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
transitionTime O TimeSpan Number (ms) An optional gradual voltage change over the given time span avoiding instantaneous jumps to simulate real-world analog behavior.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetCPVoltageResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

OCPP v2.x

SetCPVoltageRequest:

Property M/O Type JSON Type Description
voltage M Volt Number (Double) The voltage on the Charge Pilot.
voltageError O Percent Number (Double) An optional random variation within ±n% to simulate real-world analog behavior.
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
transitionTime O TimeSpan Number (ms) An optional gradual voltage change over the given time span avoiding instantaneous jumps to simulate real-world analog behavior.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetCPVoltageResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SendEVMessage

This message sends an ISO 15118 data structure, as if they would be send by an electric vehicle.

This method uses the OCPP v2.1 SEND message type, therefore there will be no direct response to this message. Nevertheless, when the the charging station can not parse this message, an error message might be send.

Text Message Format

The ISO 15118 message can be encoded as JSON, when only the processing of the messages shall be tested, or as Efficient XML(EXI) or even Ethernet frames, when lower layer parsing shall also be tested.

SendEVMessage (text):

Property M/O Type JSON Type Default Description
evse O EVSE Object - The optional EVSE and connector identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId) and (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
processingDelay O TimeSpan Number (ms) - An optional processing delay before the request is processed by the charging station.
message M JSON Object or encoded binary data as a text Object or String - The ISO 15118 EV message. Either as a JSON object or an encoded string representation of the EXI format.
messageType O/M ISO15118SimulationContentType String - The content type of the ISO 15118 EV message when it is a string, e.g. EXI, EthernetFrame, ...
messageEncoding O/M ISO15118SimulationEncoding String BASE64 When the ISO 15118 EV message is e.g. encoded as EXI (binary), which additional encoding was used to transform it into a string.
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

Binary Message Format

A more efficient way of sending binary data is to make use of HTTP WebSocket binary frames.

SendEVMessage (binary):

Property Type Binary Type Default Description
type BinaryDataMessageType UInt32 - 0x00000100
evseId EVSEId Byte 0x00 The optional EVSE identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId).
connectorId ConnectorId Byte 0x00 The optional connector identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId) and (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
processingDelay TimeSpan UInt32 (ms) 0x00000000 An optional processing delay before the request is processed by the charging station.
messageType ISO15118SimulationContentType Byte - The content type of the ISO 15118 EV message when it is a string, e.g. EXI, EthernetFrame, ...
messageLength Integer UInt32 - The length of the serialized ISO 15118 EV message
message Array<Byte> Array<Byte> - The ISO 15118 EV message as array of bytes.
signatureCount Integer Byte 0x00 Number of signatures
signatures Array<Signature> Array<Byte> - An (optional) enumeration of cryptographic signatures.

MCS Diagnostics

The following messages define diagnostics for the Megawatt Charging System (MCS). This new system is conceptually similar to the old Combined Charging System (CCS), but instead of Pulse Wide Modulation (PWM) and Power LAN Communication (PLC) it uses Single-Pair Ethernet (Multi-Drop 10BASE-T1S, IEEE 802.3cg / IEEE 802.3-2022) to communicate with the EV (ISO 15118-10) and possible other auxiliary devices between EVSE and EV. Those devices can be e.g. micro controllers, temperature, and coolant flow sensors within the charging plug and cable.

Due to the extreme voltages and currents involved, both IEC 61851-23-3 and SAE J3271 mandate rigorous monitoring of errors (state E) and faults (state F) such as cooling system failures, overtemperature, or unexpected cable disconnections. To ensure compliance, test procedures must explicitly validate system behavior in these failure scenarios. This includes verifying the correct transition into state E/F and ensuring that any hazardous conditions immediately trigger safe shutdown procedures, physical interlocks, and remote fault notifications.

Given these requirements, the use of OCPP v2.1+ is strongly recommended as it provides Charging Station Operators (CSOs) a detailed device model and real-time event stream architecture, which is required for safety, compliance, and operational continuity of critical infrastructure.

SetCEVoltage

The Charge Enable (CE) pin replaces the Charge Pilot (CP) pin of CCS, but has a similar approach to signal the current charging state (A, B, C, D, E, F) of the electric vehicle via discrete voltage levels. The voltage is measured between Charge Enable and the Protective Earth (PE), with a typical tolerance of ±0.5 volt.

CE Voltage State 10BASE-T1S EV Condition Notes
+12 V A - Not connected No vehicle connected.
+9 V B Active Connected, not requesting energy Vehicle connected (ID-Pin confirmation). EVSE activates 10BASE-T1S link, establishing a network connection with the cable’s embedded electronics and the EV. Ready for negotiation. Not charging.
+6 V C Active Connected and ready to charge EV requests charging, internal contactor closed. Locked cable on EV side.
+3 V D Active Charging with ventilation required (rare) EV requests charging, requires external ventilation (e.g. battery gas exhaust).
0 V E - Error, CE short to PE or GND Fault or EVSE disconnected. Charging stops immediately.
< 0 V F - Error, reverse polarity or other fault Communication error or invalid voltage detected.
>12 V - - Error, overvoltage fault Voltage out of specification.

The following table shows all legal transitions between EV Charge Enable states.

State Transition Allowed Description
A → B ✅ Vehicle plugged in. EVSE detects vehicle via ID-Pin, 10BASE-T1S communication initiated. No power supplied yet.
A → C ❌ Direct transition not allowed, must go through B.
A → D ❌ Direct transition not allowed, must go through B.
A → E ⚠️ Hard fault (e.g., CE shorted to PE), possibly due to damaged cable or vehicle.
A → F ⚠️ Invalid CE signal (e.g., negative voltage), possibly due to wiring fault.
B → A ✅ Vehicle unplugged. ID-Pin signals disconnection.
B → C ✅ Vehicle ready to charge, closes internal contactor. EVSE locks cable, activates cooling, and supplies power.
B → D ✅ Like C, but vehicle requests additional cooling (rare). EVSE adjusts cooling parameters.
B → E ⚠️ Unexpected fault if CE pulled to GND.
B → F ⚠️ Invalid CE voltage (e.g., < 0 V), possibly hardware defect.
C → A ❌ Direct transition not possible, as unplugging during charging is detected as a fault (→ E).
C → B ✅ Vehicle pauses charging, e.g., due to SoC or thermal reasons. Cooling remains active.
C → D ⚠️ Direct switching between cooling modes not standard; vehicle typically returns to B.
C → E ⚠️ Unexpected CE fault during charging, e.g., cable unplugged. EVSE stops power.
C → F ⚠️ Invalid signal during charging, treated as a fault. EVSE stops power.
D → A ❌ Direct transition not possible, as unplugging during charging is detected as a fault (→ E).
D → B ✅ Additional cooling no longer required.
D → C ⚠️ Direct switching between cooling modes not standard; vehicle typically returns to B.
D → E ⚠️ CE pulled to GND during charging with increased cooling. Fault condition. EVSE stops power.
D → F ⚠️ Invalid signal during charging, treated as a fault. EVSE stops power.
E → A ✅ Fault resolved, vehicle unplugged.
E → B ✅ Fault resolved, vehicle remains connected.
E → C ⚠️ Fault state requires resolution (usually return to A or B) before charging can resume.
E → D ⚠️ Fault state requires resolution (usually return to A or B) before charging can resume.
E → F ⚠️ Irrelevant, may occur during unstable or cascading faults.
F → A ✅ EVSE fault resolved, vehicle unplugged.
F → B ✅ EVSE fault resolved, vehicle remains connected.
F → C ⚠️ Fault state requires resolution (usually return to A or B) before charging can resume.
F → D ⚠️ Fault state requires resolution (usually return to A or B) before charging can resume.
F → E ⚠️ Irrelevant, may occur during unstable or cascading faults.
  +-----+     Plug-In      +-----+    Contactor Close    +-----+
  |  A  | ---------------> |  B  | --------------------> | C/D |
  +-----+                  +-----+     Supply Energy     +-----+
     ^                       | ^                            |
     |        Unplug         | |      Pause Charging        |
     +-----------------------+ +----------------------------+

SetCEVoltageRequest:

Property M/O Type JSON Type Description
voltage M Volt Number (Double) The voltage on the Charge Enable pin.
voltageError O Percent Number (Double) An optional random variation within ±n% to simulate real-world analog behavior.
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
transitionTime O TimeSpan Number (ms) An optional gradual voltage change over the given time span avoiding instantaneous jumps to simulate real-world analog behavior.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetCEVoltageResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetIDVoltage

The Insertion Detection (ID) pin detects, whether a cable is plugged into an electric vehicle or not. The exact voltage levels are not standardized, just a value range is specified. Most implementations use +5V or +12V.

Voltage Description Action
null Not connected
> 0V Connected
0V Short to PE Error State (E)
< 0V. Wiring Fault Fault State (F)

SetIDVoltageRequest:

Property M/O Type JSON Type Description
voltage M Volt Number (Double) The voltage on the Insertion Detection pin.
voltageError O Percent Number (Double) An optional random variation within ±n% to simulate real-world analog behavior.
processingDelay O TimeSpan Number (ms) An optional processing delay before the request is processed by the charging station.
transitionTime O TimeSpan Number (ms) An optional gradual voltage change over the given time span avoiding instantaneous jumps to simulate real-world analog behavior.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SetIDVoltageResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

SendSPEMessage

This message sends an ISO 15118 or IEC 61851-23-3 data structure over the Single-Pair Ethernet (10BASE-T1S), as if they would be send by the electric vehicle or other embedded electronics, e.g. within the charging cable. As multi-drop 10BASE-T1S is a half-duplex protocol the EVSE is specified as dedicated "bus master" which coordinates the Physical Layer Collision Avoidance (PLCA) on the communication bus.

Device Node Id Description
EVSE 0 Bus Master
EV 1 Electric Vehicle
Connector 2 -
Inlet 3 -
Adaptor 4 -
- 5-7 reserved

After the ID-Pin confirms the EVSE-to-EV connection and the EV signals state B via the Charge Enable-Pin, the EVSE provides auxiliary power to the cable’s communication module(s) and sends a discovery message via 10BASE-T1S to identify connected devices (IEC 61851-23-3).

Alternatively the auxiliary power can be always on, to monitor whether the charging cable "still exists". This helps to detect "cable theft", a common costly problem for Charging Station Operators (CSOs) worldwide.

According to ISO 15118-20 and IEC 61851-23-3 IPv6 with Link-Local Addressing must be used for the 10BASE-T1S communication, aligning it with automotive Ethernet standards. There is a dedicated 10BASE-T1S network per EVSE. Charging stations with multiple EVSEs have to support IPv6 Link-Local Routing with additional ethernet/EVSE device information.

The standards also define, the EVSE (SECC) as the initiator of the Single-Pair Ethernet communication, with cable electronics and EV (EVCC) only responding to EVSE requests. Yet, during charging states C or D, the EV and cable continuously monitor and report conditions like coolant temperature, flow rate, or electrical faults. If a fault is detected, e.g., coolant leak or overheating, the EV or cable sends an unsolicited alert, triggering a transition to fault state E or F. The microcontrollers use dedicated time slots for this kind of urgent communication.

Currently the cable communication is not yet standardized, but such a cable information might look like this:

{
  "cableId":           "MCS-3000A-LC-001",
  "cableCertificate":  "0x00...",
  "maxVoltage":         1250,
  "maxCurrent":         3000,
  "coolingType":       "liquid",
  "coolantStatus":     "operational",
  "temperature":        25.5
}

Text Message Format

The ISO 15118 message can be encoded as JSON, when only the processing of the messages shall be tested, or as Efficient XML(EXI) or even Ethernet frames, when lower layer parsing shall also be tested.

SendSPEMessage (text):

Property M/O Type JSON Type Default Description
evseId M EVSEId Number - The EVSE identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId).
connectorId O ConnectorId Number - The optional connector identification, when the charging station has more than one connector for the given EVSE (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
processingDelay O TimeSpan Number (ms) - An optional processing delay before the request is processed by the charging station.
message M JSON Object or encoded binary data as a text Object or String - The ISO 15118 EV message. Either as a JSON object or an encoded string representation of the EXI format.
messageType O/M ISO15118SimulationContentType String - The content type of the ISO 15118 EV message when it is a string, e.g. EXI, EthernetFrame, ...
messageEncoding O/M ISO15118SimulationEncoding String BASE64 When the ISO 15118 EV message is e.g. encoded as EXI (binary), which additional encoding was used to transform it into a string.
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

Binary Message Format

A more efficient way of sending binary data is to make use of HTTP WebSocket binary frames.

SendSPEMessage (binary):

Property Type Binary Type Default Description
type BinaryDataMessageType UInt32 - 0x00000100
evseId EVSEId Byte - The EVSE identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId).
connectorId ConnectorId Byte 0x00 The optional connector identification, when the charging station has more than one connector for the given EVSE (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
processingDelay TimeSpan UInt32 (ms) 0x00000000 An optional processing delay before the request is processed by the charging station.
messageType ISO15118SimulationContentType Byte - The content type of the ISO 15118 EV message when it is a string, e.g. EXI, EthernetFrame, ...
messageLength Integer UInt32 - The length of the serialized ISO 15118 EV message
message Array<Byte> Array<Byte> - The ISO 15118 EV message as array of bytes.
signatureCount Integer Byte 0x00 Number of signatures
signatures Array<Signature> Array<Byte> - An (optional) enumeration of cryptographic signatures.

Diagnostic Monitoring

Diagnostic Monitoring shall allow e.g. CPOs to monitor the communication of for example a charging station with internal and external connected devices like the electric vehicle (ISO 15118 communication), energy meters (Modbus RTU/TCP/UDP), time servers (NTP/NTS) and so on.

Important for efficient monitoring and to avoid an overload of the charging station to CSMS connection are monitoring filters and the ability to support more than one monitor for each device or communciation flow.

GetDiagnosticMonitorDevices

This request will return a list of all devices or communication flows, that support Diagnostic Monitoring and their mandatory and optional configuration parameters.

GetDiagnosticMonitorDevicesRequest:

Property M/O Type JSON Type Description
match O String String An optional include filter for string matching monitor names or descriptions.
evseId O EVSEId String The optional EVSE Id filter (0 > EVSEId ≤ MaxEVSEId)
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

GetDiagnosticMonitorDevicesResponse:

Property M/O Type JSON Type Description
devices M Array<MonitoringDevice> Array<Object> The list of all matching Diagnostic Monitor Devices.
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

MonitoringDevice:

Property M/O Type JSON Type Description
id M MonitoringDeviceId String The identification/name of the Diagnostic Monitor Devices.
description O I18NString Array<String> A multi-language description of the device.
filters O Array<MonitoringDeviceFilter> Array<Object> An optional list of available filters.
maxInstances O UInt16 Number (Integer) Maximum number of concurrent monitors of this type.
runningInstances O UInt16 Number (Integer) Current number of running monitors of this type.

ToDo: Would a mapping to the device model make sense?

SetupDiagnosticMonitor

This message sends some ISO 15118 data structure as if they would be send by an electric vehicle. Maybe JSON encoding, as this is for testing anyway. Maybe also EXI when also lower layer decoding shall be tested.

SetupDiagnosticMonitorRequest:

Property M/O Type JSON Type Default Description
monitoringDeviceId M MonitoringDeviceId String - The identification/name of the Diagnostic Monitor Devices.
evse O EVSE Object - The optional EVSE and connector identification, when the charging station has more than one EVSE (0 > EVSEId ≤ MaxEVSEId) and (0 > ConnectorId ≤ MaxConnectorId(EVSEId)).
format O DiagnosticMonitoringStreamFormat String JSON | BINARY
signatures M/O Array<Signature> Array<Object> - An (optional) enumeration of cryptographic signatures.

SetupDiagnosticMonitorResponse:

Property M/O Type JSON Type Description
diagnosticMonitorId M DiagnosticMonitorId String The identification of the Diagnostic Monitor instance.
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

DisableDiagnosticMonitor

DisableDiagnosticMonitorRequest:

Property M/O Type JSON Type Description
monitoringDeviceId M MonitoringDeviceId String The identification/name of the Diagnostic Monitor Devices.
diagnosticMonitorId M DiagnosticMonitorId String The identification of the Diagnostic Monitor instance.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

DisableDiagnosticMonitorResponse:

Property M/O Type JSON Type Description
status M GenericStatus String The response status.
statusInfo O StatusInfo Object Optional extended status information.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

Diagnostic Tools

Diagnostic Tools are small asynchronous applications running e.g. on the charging station for self- and integration testing and diagnoses. They follow the concept of AI applications using the Model Context Protocol (MCP) and thus might not only return a single response, but also multiple intermediary responses or status updates.

These tools might be very vendor specific and AI agents should be able to consume then without requiring external tool specifications. Therefore all tools provide their own extensive meta data about their input and output data formats.

Ping

Send one or multiple ICMP echo request to the specified DNS name or IP address. Optional with the Record Route extension.

Traceroute

Trace the IP route to the specified DNS name or IP address using the traceroute approach.

TestCSMSNetworking

This tool will test whether the network configuration to access a CSMS is complete, free of contradictions, report TLS parameters and test whether the tools can successfully log into the (new) CSMS. This will in particular avoid costly downtimes caused by CSMS migrations which often fail because of unexpected configuration or network issues.

TestNetworkTimeSecure

This tool tests whether the configured Network Time Security (NTS) time servers are configured correctly (complete, free of contradictions) and whether they can be reached, and reports the NTP/NTS time information received.

It is specified as two requests of the Secure Time Synchronization white paper (section 3.2.7). Both are answered at once, and report their outcome in a NotifyNetworkTimeResultRequest:

The steps of a test are written for people and diagnostic agents to read; what a machine is to evaluate is in the other properties. A diagnostic agent typically proceeds as follows:

  1. It reads the state: NTPController.LegalTime and LegalTimeReason, ErrorsInARow, Limited and LastCheck of the group, and Problem of its clients, via GetVariablesRequest.
  2. It sends TestTimeServer for every client whose Problem is true, or for every client of the group, one after the other.
  3. It reads failedAt, and the steps of that stage:
    • NameResolution: the name resolution of the charging station (Secure Name Resolution).
    • Connection: the server is down, or TCP port 4460 (or the SSH port) is blocked on the way.
    • ServerAuthentication: RootCAs, the installed NetworkTimeRootCertificates and the pins; a certificate that ran out, or a clock so far off that a valid certificate looks invalid (NoCertTimeCheckAfterReboot).
    • KeyExchange: the server refuses the request, or offers none of the AEAD algorithms of the client.
    • TimeRequest: UDP port 123 is blocked, or a stateful firewall or a NAT drops the answer.
  4. Once the cause is removed, it sends one SyncNetworkTime, to confirm that the group produces a time again and, for the legal group, that the time is legal time.

Reference implementation: the command syncNTS [<group>] [<time server>] of the command lines of Open Charging Cloud does the same, at the console and over SSH: without a time server it is SyncNetworkTime, with one TestTimeServer. The messages of OCPP 2.1 and OCPP 1.6 are implemented in WWCP_OCPP. The CSMS of Open Charging Cloud (CSMSCLI) sends them from its command line as stationSyncNTS <station> [<group> | @<client>] and writes what the station tells in the lines of syncNTS: the command an agent following the procedure above types.

QueryDNS

This tool asks the charging station to resolve a name the way the charging station itself resolves names: with its own name servers, transports, pins and root CAs (see Secure Name Resolution for OCPP), and from its own place in the network. It answers the questions a CSMS cannot answer from its own side: whether the charging station resolves the name of a (new) CSMS or of its NTS-KE servers at all, which name server answered, whether the certificate of a name server reached over DNS-over-TLS or DNS-over-HTTPS was accepted, and, where the charging station validates DNSSEC, whether the answer is secure. Typical uses are the preparation of a CSMS migration (see TestCSMSNetworking), a failing NTS key exchange (see TestNetworkTimeSecure), and the DNS-published records (SRV, SVCB, TXT, TLSA) of Critical Legal Time Services. The request and its response are small and fully described below, so that an AI agent can call the tool through the CSMS without any further tool specification.

Which name servers are asked. Without serverId (server in OCPP v1.6), the question is put to the configured name servers exactly as every other service of the charging station puts it, including its cache: the answer is the one the charging station would work with. With serverId, only this one configured name server is asked, and without the cache, so that the answer says what this server answers now. Only configured name servers can be named. A charging station SHALL NOT ask a name server it is not configured with: its firewall rules admit only those (Secure DNS, section 4.1), and a charging station that queries arbitrary addresses on request would be a probe inside the operator's network. A name server configured by its domain name cannot be asked on its own, because its own name would have to be resolved first, which is the thing being tested.

Which name is asked. name is a domain name or an IP address. An IP address is turned into its reverse name (in-addr.arpa, RFC 1035 §3.5; ip6.arpa, RFC 3596 §2.5), which is asked for PTR unless other record types are given, and the response says so in reverseLookupOf.

One response. Unlike the other tools, QueryDNS needs no intermediary responses: a query ends within the query timeout of the name servers (DNSClientController.QueryTimeout, at most 120 seconds, usually a few) and its retries, and the response carries the whole result. A CSMS SHALL wait at least DNSClientController.QueryTimeout × (MaxRetries + 1) for it.

Accepted and Rejected. Accepted means that the question was put. What came of it — an answer, NXDomain, a timeout, a refused certificate — is part of the response and no reason for Rejected. Rejected means that nothing was asked, for one of these reasons, given as statusInfo.reasonCode in OCPP v2.x and as reasonCode in OCPP v1.6, and in words in error in both versions:

reasonCode Meaning
Disabled Name resolution is switched off (DNSClientController.Enabled = false).
UnknownServer serverId (server) names no configured name server.
ServerByName The name server is configured by its domain name and cannot be asked on its own.
InvalidName name is neither a domain name nor an IP address.
InvalidRecordType A record type is neither a mnemonic of the IANA registry, nor a number, nor of the form TYPE and a number.
TooManyRecordTypes More than 8 record types were asked for.

Who asked. QueryDNS changes nothing on the charging station, but makes it send queries. A charging station SHALL write every QueryDNS into its log, with the CSMS that asked and what came back, and MAY require the request to be signed by an entity with diagnostic rights, as for Diagnostic Control requests.

OCPP v1.6

QueryDNSRequest:

Property M/O Type JSON Type Description
name M String String (≤ 255) The domain name or IP address to look up.
recordTypes O Array<String> Array<String> The record types to ask for, at most 8, each the mnemonic of the IANA registry (e.g. A, AAAA, SRV, TLSA), its number, or the generic form of RFC 3597 §5 (TYPE65). Default: A and AAAA, or PTR for an IP address.
server O Integer Number (Integer ≥ 1) The one name server to ask, as the n-th server of the configuration key dns.servers. Default: all of them, the way the charging station resolves names.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

QueryDNSResponse:

Property M/O Type JSON Type Description
status M GenericStatus String Accepted when the question was put, Rejected when nothing was asked.
reasonCode O String String With Rejected: the reason code of the table above.
name O String String The name that was asked: name of the request, or the reverse name made of its IP address.
reverseLookupOf O String String The IP address of the request, where its reverse name was asked instead.
recordTypes O Array<String> Array<String> The record types that were asked for.
server O Integer Number The one name server that was asked, where the request named one.
answeredBy O String String The name server the answer came from, as transport://address:port, e.g. tls://192.0.2.53:853.
responseCode O String String The RCODE of the answer, as the name of the IANA registry (NoError, NXDomain, ServFail, Refused, …) or as its number. Absent when no answer came.
authoritative O Boolean Boolean The Authoritative Answer bit of the answer.
truncated O Boolean Boolean The Truncation bit of the answer.
timedOut O Boolean Boolean Whether no name server answered within its query timeout.
dnssec O String String The security status the charging station validated the answer to, one of the four of RFC 4033 §5: Secure, Insecure, Bogus, Indeterminate. Absent where the charging station did not validate it.
runtime O Integer Number (Integer ≥ 0) How long the query took, in milliseconds.
answers O Array<DNSAnswer> Array<Object> The records of the answer section, at most 200.
omittedAnswers O Integer Number (Integer > 0) How many further records of the answer section were left out.
certificates O Array<NameServerCertificate> Array<Object> What the charging station made of the certificates of the name servers it asked over TLS or HTTPS during this query.
error O String String Why nothing was asked (Rejected), or why no answer was received (Accepted), in words.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.

DNSAnswer:

Property M/O Type JSON Type Description
name M String String The owner name of the record.
type M String String Its record type, as the mnemonic of the IANA registry or, where it has none, in the generic form of RFC 3597 §5 (TYPE65534).
ttl M Integer Number (Integer ≥ 0) Its time to live, in seconds.
value M String String Its data in presentation format (RFC 1035 §5.1), e.g. 192.0.2.80 or 10 5 4460 ntp.example.org..

NameServerCertificate:

Property M/O Type JSON Type Description
server M String String The name server, as it was asked.
accepted M Boolean Boolean Whether the connection went ahead.
status M String String The verdict, with the values of DNSServerController.CertificateStatus (Secure DNS, section 3.1.2): Accepted, Recorded, Tolerated, PinMismatch, Untrusted, WrongName, NoCertificate.
certificateFingerprint O String String The SHA-256 fingerprint of the certificate the server showed.
rootFingerprint O String String The SHA-256 fingerprint of the root CA its chain ended at.

OCPP v2.x

QueryDNSRequest:

Property M/O Type JSON Type Description
name M String String (≤ 255) The domain name or IP address to look up.
recordTypes O Array<String> Array<String> As in OCPP v1.6.
serverId O String String (≤ 50) The one name server to ask, as the instance of its DNSServerController (Secure DNS, section 3.1.2). Default: all of them, the way the charging station resolves names.
signatures M/O Array<Signature> Array<Object> An (optional) enumeration of cryptographic signatures.
customData O CustomData Object Optional custom data.

QueryDNSResponse:

The properties of OCPP v1.6, with statusInfo instead of reasonCode and serverId instead of server, and:

Property M/O Type JSON Type Description
statusInfo O StatusInfo Object With Rejected: the reasonCode of the table above, and error as additionalInfo.
serverId O String String The one name server that was asked, where the request named one.
customData O CustomData Object Optional custom data.

Example: the NTS-KE server of the legal time, asked of the first name server alone, which is reached over DNS-over-TLS:

[2, "19223201", "QueryDNS", {
    "name":        "ntske1.cpo.example",
    "recordTypes": [ "A", "AAAA" ],
    "serverId":    "dns-1"
}]
[3, "19223201", {
    "status":         "Accepted",
    "name":           "ntske1.cpo.example.",
    "recordTypes":    [ "A", "AAAA" ],
    "serverId":       "dns-1",
    "answeredBy":     "tls://192.0.2.53:853",
    "responseCode":   "NoError",
    "authoritative":  false,
    "truncated":      false,
    "timedOut":       false,
    "runtime":        38,
    "answers": [
        { "name": "ntske1.cpo.example.", "type": "A", "ttl": 3600, "value": "198.51.100.123" }
    ],
    "certificates": [
        { "server": "192.0.2.53", "accepted": true, "status": "Accepted",
          "certificateFingerprint": "41C7…3F61", "rootFingerprint": "9D2E…D8E" }
    ]
}]

Reference implementation: Both versions. The charging station answers QueryDNS with the same result as the DNS test of its local web interface (POST /api/v1/configuration/dns/query) and the queryDNS command of its command line, which every kind of node of the reference implementation has: queryDNS <name> [<record type> …] [@<server>], where a server is named by its id, its place in the list or its address. The command line of the CSMS sends the request to the charging station it is working with: queryDNS <name> [<record type> …] [@<serverId>], in OCPP v1.6 [@<n>].